Part Number Hot Search : 
SU802833 IN74HC IN24LC16 BC327 E12KG2C HCF4002 TC9134P ULN2004L
Product Description
Full Text Search
 

To Download NS-SERIES Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  ns, the hmi brand you can rely on programmable terminals best match machine management proven reliability ? ? ? ns series
expanding markets in emerging countries, short product cycles, and diversifying customer needs are just some of the factors that create drastic changes for the production industry. to win in severe global market competition, you have to continue to grasp industry changes quickly, understand user needs accurately, and provide diverse forms of added value. omron will help you handle ever-changing customer needs with the three keywords of the ns series. machine control at your fingertips. on-screen machine management. best match omron has provided even greater compatibility with omron plcs and components to provide an advanced design process that lets you achieve appealing machines. machine management the ns series transforms machine hmis from simple operation panels and turns them into machine management tools. proven reliability the NS-SERIES pts have a proven track record that will take your machines to a higher level of reliability. let your machines evolve ns, the hmi brand you can rely on 2
the best match possible the amount of work and cost of connecting to omron plcs and components have been greatly reduced. the results is an incredible range of features that is possible only when unifying to one manufacturer. connecting to the nj-series machine automation controller allows the machine designer to quickly achieve the features required by the user through support for improved troubleshooting and structured programming with structures and other new data types. machine management tool the machine designer can easily implement plc troubleshooting, machine troubleshooting, settings for servo drives, temperature controllers, and other control components, status monitoring of connected devices, and uploading/downloading of parameters. proven reliability in the ten years since initial marketing, omron has globally supplied numerous hmi solutions with the highly reliable ns series at over 200 sales and service centers around the world. 3
ns series lineup this powerful lineup showcases omron's unique value. choose from 3 types to match your application and requirements. ns series hand-held pt cable 15 inches 12 . 1 inches 10 . 4 inches 5 . 7 inches 5 . 7 inches 5 . 7 inches standard models rs-232c rs-422a usb slave usb master ethernet rs-232c x 2 controller link rgb output video ( rgb input only ) rs-422a/485 memory card ladder monitor usb slave usb master ethernet rs-232c x 2 controller link video memory card ladder monitor usb slave usb master ethernet rs-232c x 2 controller link video memory card ladder monitor usb slave ethernet rs-232c x 2 memory card usb slave rs-232c/422a memory card usb slave rs-232c/422a memory card ns15-tx ns12-ts ns10-tv ns5-tq nsh5-sqr 4 nsh5-sqg plentiful screen variations and diverse functions allow use in a wide variety of applications. nsh series hand-held models a hand-held version of the ns5 is now available to perform operations at the production site. in ch es d models plentiful scree color tft inches n s 1 ns1 ns1 ns1 e in a wide variety of application s. color tft 4 i n c h es ns10 t n s 1 0 t n s 1 0 -t n s 1 0 - t color tft 7 in ch es ns5 tq ns5 tq ns5 - tq color high-iuminance tft 7 inches nches usb slave n sh5-sq r d m o del s a hand-held v e color tft 7 inches ches usb slav e nsh5 sqg nsh5 sqg nsh5 - sqg ns 5 is now available to p erform o p color tft 32,768 colors xga 1024 x 768 pixels screen memory size: 60 mb 32,768 colors svga 800 x 600 pixels screen memory size: 60 mb 32,768 colors vga 640 x 480 pixels screen memory size: 60 mb 32,768 colors qvga 320 x 240 pixels screen memory size: 60 mb 32,768 colors qvga 320 x 240 pixels equipped with a red switch for an emergency stop input. emergency stop (3 inputs) equipped with a gray switch for a stop input. emergency stop (3 inputs) 32,768 colors qvga 320 x 240 pixels 5 . 7 inches usb slave ethernet rs-232c x 2 memory card ns5-sq 7 in ch es ns5 sq ns5-sq ns5 - sq color tft 32,768 colors qvga 320 x 240 pixels screen memory size: 60 mb 8 . 4 inches usb slave usb master ethernet rs-232c x 2 ladder monitor memory card video ns8-tv 4 i n ches ns8 t v ns8 t v n s 8 -tv n s 8 - tv v v v color tft 32,768 colors vga 640 x 480 pixels screen memory size: 60 mb
without screen creation and ladder programming, the cx-designer screen design software is so easy-to-use that anyone can master it. ns-runtime cx-designer this software enables plc communications from a personal computer by manipulating pt screens created using the cx-designer. m3d software usb slave usb master ethernet rs-232c x 3 controller link ladder monitor devicenet memory card usb slave usb master ethernet rs-232c x 3 controller link ladder monitor devicenet memory card nsj12-ts -g5d nsj10-tv -g5d nsj8-tv -m3d nsj8-tv -g5d nsj5-tq -m3d/-g5d nsj5-sq -m3d/-g5d 5 nsj series integrated controller models pt is unified with the controller into one package to greatly help standardize equipment and reduce size. 12 . 1 inches (controller section) n s j 1 2 nsj12 nsj12 oller models pt is unified with t in ch es color tft nsj8 tv color tft nsj8 tv color tft 10 . 4 inches 8 . 4 inches 8 . 4 inches nsj5 sq m color tft 5 . 7 inches 5 . 7 inches n s j 1 0 nsj10 nsj10 greatly help standardize equipment 4 in ch es color tft nsj5 tq m3d/ g 7 inc h es color high-iuminance tft 32,768 colors svga 800 x 600 pixels screen memory size: 60 mb i/o points: 1,280 data memory: 128k words program capacity: 60k steps (controller section) i/o points: 640 data memory: 32k words program capacity: 20k steps (controller section) (controller section) i/o points: 640 program capacity: 20k steps data memory: 32k words g5d i/o points: 1280 program capacity: 60k steps data memory: 128k words m3d i/o points: 640 program capacity: 20k steps data memory: 32k words g5d i/o points: 1280 program capacity: 60k steps data memory: 128k words (controller section) i/o points: 1,280 data memory: 128k words program capacity: 60k steps (controller section) i/o points: 1,280 data memory: 128k words program capacity: 60k steps 32,768 colors vga 640 x 480 pixels screen memory size: 60 mb nsj8-tv nsj8-tv 3d m3 - m v tv ords pro g ram ca p p p ac i i i t y : 20k step s s s usb slave usb master ethernet rs-232c x 3 controller link ladder monitor devicenet memory card nsj8-tv p nsj8-tv d g5 - g v tv w ord s p ro g ram ca p p p ac it t t y: 60k st eps s s usb slave usb master ethernet rs-232c x 3 controller link ladder monitor devicenet memory card 32,768 colors vga 640 x 480 pixels screen memory size: 60 mb nsj5-s q t n nsj5-s q 3d/ - g5 m3 m q -m s q ty: 20k steps 2k wor d s ty: 20k steps n) s s y d s p s p i g i g p d ata m emo ry program cap program cap i g i po program c ap i/o points: 12 g5d i/o points: 12 y y p y 128k wor ds y p p y: 1 pa p p 2 2 s s ity: 60k st eps paci paci s s it y: 60k st eps 0 0 i paci 0 280 0 280 usb slave ethernet rs-232c x 3 controller link devicenet memory card 32,768 colors qvga 320 x 240 pixels screen memory size: 60 mb nsj5-t q y n nsj5-t q g 5 3d/ - g m3 q - m t q y: 20k steps 2k word s y: 20k steps n) data memo ry d p i/ p i/ g i/ g p data m emo ry program c apa / program c apa / g / /o points: 12 program capa /o po int s: 12 g5d /o points: 12 y: 128k words yp y: 128k wor ds yp y: 12 acit a 2 a 2 2 s s ty: 60k steps a cit acit s s ty: 60k st eps t 280 acit 28 0 280 usb slave ethernet rs-232c x 3 controller link devicenet memory card 32,768 colors qvga 320 x 240 pixels screen memory size: 60 mb 32,768 colors vga 640 x 480 pixels screen memory size: 60 mb
a revolutionary best ma the NS-SERIES pts provide revolutionary compatibility with the road-proven cs/cj-series the new nj-series controllers to achieve even greater added value in user machines. 6 the nj-series machine automation controllers revolutionize productivity you can create a flexible, high-speed, high-precision system based on the nj-series machine automation controllers. use tags to access any memory areas, or troubleshoot machines and systems by using the NS-SERIES pts to make the most of the strengths of the nj-series controllers and to manage machines. ethercat ethernet/ip
tch plcs and 7 the cs/cj-series plcs for the reliability of a proven track record features are provided to easily connect to cs/cj-series plcs to take advantage of their proven track record. many features that do not require screen creation or programming support everything from design through maintenance to take advantage of the compatibility of omron plcs and pt and to serve as the face of your machines.
power support for all user from conceptual designs through commissioning, operation, and maintenance, the ns design plentiful graphing functions ns screen templates cx-designer screen design software screen data security functions device data transfer 8 reduced work 19 p 20 p 20 p 21 p 25 p 22 p - troubleshooter 17 p 18 p 16 p 12 p - 11 p multifunction objects multi-language support best match with omron products smart active prarts (sap) with ethernet/ip direct connection to temperature controllers face plate auto-builder for ns plc troubleshooter machine troubleshooter for machine automation controllers nj-series nj troubleshooter integrated NS-SERIES pt simulation 10 p new
needs series supports every user need. 9 startup/operation maintenance features for reliability and complete maintenance attractive, convenient features for easier operation 28 p 29 p 29 p 26 p 26 p 27 p 27 p single port multi access ladder monitor plc data trace 28 p comparison operating log user security functions ftp function analog rgb output 260,000-color video display 31 p 30 p - led backlight 27 p new
10 no work is required to create alarm screens. frames for alarm screens are provided as standard features in the NS-SERIES pts. you do not need to create screens to complete alarm screens. management of the meanings of alarms is unified on the controller, so you do not have to register, add, or correct addresses on the NS-SERIES pts. user-defined errors sysmac studio unified alarm definitions no screen creation is required alarm registration and programming detection conditions nj controller copy and paste alarms displayed transfer alarm specifications excel nj troubleshooter improved debugging efficiency "integrated simulation" of sysmac studio enables offline debugging of the screen data for the NS-SERIES pts and sequence program for the nj-series on the computer. * sysmac studio version 1.02 or higher (cx-designer version 3.41 or higher) is required. integrated NS-SERIES pt simulation standard feature for nj-series controllers errors are automatically detected and displayed on-screen along with corrective actions for the cpu unit function modules, ethercat slaves, and cj-series units that are connected in the nj-series controller. whenever an error might occur, you can recover normal operation quickly to reduce downtime without using user manuals or support software on a computer. controller errors for machine automation controllers nj-series use integrated NS-SERIES pt simulation or nj troubleshoot by using the NS-SERIES pts to make the most of the strengths of the nj-series controllers and to manage machines. nj controller test screen of cx-designer appears after synchronization of sysmac studio, and integrated simulation starts. select integrated simulation. select image data and host to simulate.
11 design startup/operation maintenance ns-runtime features network system configuration ordering information specifications hand-held pt in conjunction with an alarm bit (see note.) alarm bit 10.01 on (no paper) alarm bit 10.02 on (printing error) troubleshooter a troubleshooter is provided for the connected omron controller or plc. this greatly reduces work requirements. specific example cs/cj-series plc troubleshooter constantly monitors plc errors. automatically detects plc errors and displays the error details and recovery procedure on the screen. even if a problem occurs, it can be resolved quickly without referring to the manuals. machine troubleshooter easier design of machine error screens individual error screens that were previously made for each error can now be integrated into one. it is possible to switch only the error details (text and screen) without ladder programming in conjunction with the alarm bit. cs/cj/cp-series plc a special template is required when using this function. the screen template is supplied with cx-designer of version 2.1 or later. this function is a standard feature in the nsj-series pts. note: alarms, plc/pt memory, and other items can be selected for the switching trigger. note: with this system, this frame is shared, and the error details in the pink frames are switched with an alarm or other item as the trigger. text selection image selection ns - run un tim tim e e h an d
12 best match with omron products temperature controllers temperature controllers servomotor servo driver vision sensor 260,000-color video input remote i/o terminal cpu bus units and special i/o units inverter plc plc data trace ns series is the most suitable hmi for the system that comprises omron components. the advantage is the "compatibility (reducing programming and screen data creation work)" which will reduce the amount of designing work. ns no screen designing / no programming plc cpu unit monitoring screen device monitor sap library troubleshooting
13 design startup/operation maintenance ns-runtime features network system configuration ordering information specifications hand-held pt smart active parts (sap library) dramatically reduces the effort required to create ladder programming and screens. more than 3,000 library parts (smart active parts) are available, which can directly access omron plcs and components. the objects can just be pasted from the smart active parts (sap library) library to the screen; it is completely unnecessary to create screens and ladder programming. cpu bus unit and special i/o unit troubleshooting can be also performed with the sap library. a troubleshooter sap library is available to troubleshoot each unit in the plc. when an error occurs in a unit, the troubleshooter sap library provides an easy-to-understand explanation of the cause of the error as well as the countermeasures. troubleshooter sap for basic i/o unit ncf unit setting screen devicenet monitoring screen from to computer support tools plc cpu unit monitoring screen example screens using support tool objects (tool function sap library) support tool objects can be incorporated to check for errors and make settings, even without a computer. plenty of support tool objects (the tool function sap library) are available, which can be easily incorporate support tool functions in the NS-SERIES pt. just paste the support tool objects in the screen to check for errors and make settings, even without a computer. access access cx-designer screen design software the temperature controller's setting and monitor screens are completed in no time. sap library, temperature controller parts troubleshooter sap for a position control unit the troubleshooter sap library is included as a standard feature for the cx-one and cx-designer. for details, refer to page 56. successive development for ethernet units and mc units is planned for the future. note:
15 14 design startup/operation maintenance ns-runtime features network system configuration ordering information specifications hand-held pt design time is shorten e number_produced number_of_times ? undetermined address undetermined ? specifications tag name simultaneous and parallel engineering the host applications can be designed using the tag names of the plc and pt. parallel development will shorten the design time. ethernet/ip support for data structures this special feature is made possible by combining an omron cj2 plc with an NS-SERIES pt. the data structures that you define on the programming tool can be used on the cx-designer simply by dragging and dropping them. minimize side effect of address changes it is possible to access memory with tags, so the pt and host application are not affected even if the address of data in the plc is changed. ethernet/ip ns series cj2/nj programming tool cx-designer tag access a tag is a name given to an address. tags are managed in the cj2 cpu unit, where they are defined as network symbols. the common user-defined tag names are used from programmable terminals and host applications to access memory in a cj2 cpu unit without knowing the physical address. accessed by tag name. cj2/nj cj2/nj number_produced number_produced data links 3. all devices will access with common ?tag? ns series number_produced host application address tag name d100 number_produced 2. for example, create screens with tag names without typing the physical address. 1. tag names are managed at the plc with the cx-programmer. from to by simply setting tag names, plc and programmable terminal programming can be performed in parallel. case 1 previously, the plc program was first created, and then the ladder program was referenced to create the screens. case 2 the screen graphics are created in advance, and then addresses are allocated and checked after the ladder program is completed. design time is shortened. addresses are determined while creating the ladder program. ladder program is created. the screens are created. ns series the screens are created with no need to pay attention to addresses. cj2/nj the addresses are set. plc ladder program is created. ladder program is created. plc programmable terminal screens are created. programmable terminal programmable terminal addresses are allocated and the allocations are checked programmable terminal screens are created (graphics only). programmable terminal with the cx-programmer, the address for the tag named ?number_produced? is changed from d100 to h200. specific example applications and the pt are accessed using tags, and so changes do not need to be made at other devices. even after the change, the number of items produced is acquired correctly from h200. 1. 2. address tag name d100 number_produced number_produced number_produced h200 number_produced change cj2/nj accessed using a tag. host application ns series no change required. an ethernet/ip connection is required. for cj2 series, cx-designer version 3.2 or later, and ns system version 8.4 or later are required. for nj5, cx-designer version 3.3 or later, and ns system version 8.5 or later are required. for nj3, cx-designer version 3.4 or later, and ns system version 8.61 or later are required.moreover, the multidimensional array is supported in the combination with nj. note: definition of the "motor" symbol drag & drop no change required.
15 14 design startup/operation maintenance ns-runtime features network system configuration ordering information specifications hand-held pt design time is shorten e number_produced number_of_times ? undetermined address undetermined ? specifications tag name simultaneous and parallel engineering the host applications can be designed using the tag names of the plc and pt. parallel development will shorten the design time. ethernet/ip support for data structures this special feature is made possible by combining an omron cj2 plc with an NS-SERIES pt. the data structures that you define on the programming tool can be used on the cx-designer simply by dragging and dropping them. minimize side effect of address changes it is possible to access memory with tags, so the pt and host application are not affected even if the address of data in the plc is changed. ethernet/ip ns series cj2/nj programming tool cx-designer tag access a tag is a name given to an address. tags are managed in the cj2 cpu unit, where they are defined as network symbols. the common user-defined tag names are used from programmable terminals and host applications to access memory in a cj2 cpu unit without knowing the physical address. accessed by tag name. cj2/nj cj2/nj number_produced number_produced data links 3. all devices will access with common ?tag? ns series number_produced host application address tag name d100 number_produced 2. for example, create screens with tag names without typing the physical address. 1. tag names are managed at the plc with the cx-programmer. from to by simply setting tag names, plc and programmable terminal programming can be performed in parallel. case 1 previously, the plc program was first created, and then the ladder program was referenced to create the screens. case 2 the screen graphics are created in advance, and then addresses are allocated and checked after the ladder program is completed. design time is shortened. addresses are determined while creating the ladder program. ladder program is created. the screens are created. ns series the screens are created with no need to pay attention to addresses. cj2/nj the addresses are set. plc ladder program is created. ladder program is created. plc programmable terminal screens are created. programmable terminal programmable terminal addresses are allocated and the allocations are checked programmable terminal screens are created (graphics only). programmable terminal with the cx-programmer, the address for the tag named ?number_produced? is changed from d100 to h200. specific example applications and the pt are accessed using tags, and so changes do not need to be made at other devices. even after the change, the number of items produced is acquired correctly from h200. 1. 2. address tag name d100 number_produced number_produced number_produced h200 number_produced change cj2/nj accessed using a tag. host application ns series no change required. an ethernet/ip connection is required. for cj2 series, cx-designer version 3.2 or later, and ns system version 8.4 or later are required. for nj5, cx-designer version 3.3 or later, and ns system version 8.5 or later are required. for nj3, cx-designer version 3.4 or later, and ns system version 8.61 or later are required.moreover, the multidimensional array is supported in the combination with nj. note: definition of the "motor" symbol drag & drop no change required.
16 ns series csv tag file for loop controller ns project file face plate auto-builder for ns direct connection to temperature controllers connect omron temperature controllers directly to the NS-SERIES pt. omron temperature controllers can be connected directly to the NS-SERIES pt's rs-232c port. data does not pass through the plc, so ladder programming is not required. also, there are plenty of objects in the sap library for temperature controllers, and temperature controller screens can be created easily just by pasting objects from the sap library to the screens. face plate auto-builder for ns screens for loop controllers can be easily and automatically created. significantly reduces the effort required to combine a loop controller with an NS-SERIES pt. easy automatic generation of faceplates, such as faceplates for pv monitoring and sv setting, as well as tuning screens, such as screens to set and autotune pid constants. a total of 17 function blocks are supported, with eleven function blocks, such as ratio setting and motor manipulators newly supported (version 3 of higher). comments are automatically entered for automatically assigned unit and scale settings when a project is generated (version 3 and higher). cj1w-cif11 rs-422a serial adapter omron temperature controllers omron temperature controllers an rs-422a serial adapter is needed to connect directly to a temperature controller. refer to page 53 for a list of the temperature controllers that can be connected. a conversion unit is not required to connect to the rs-422a/485 serial interface of the ns15. note: created screens are easily transferred to the ns by using a memory card or over the network. note: refer to the plc-based process control catalog (cat. no. p051) and the loop-control cpu unit catalog (cat. no. r128) for details on loop controllers. sysmac cs/cj-series loop controller (loop controller programming software) cx-process tool loop controller program creation (function block method) csv tag file output (ns screen creation software) cx-designer editing created data creation of other required screens
17 design startup/operation maintenance ns-runtime features network system configuration ordering information specifications hand-held pt the labels' text attributes can also be reflected when importing. multi-language csv data ns series thai displays also supported csv language a screen data ns project csv attachment csv attachment dual-language screen data ns project csv or unicode text when screen data is imported, text attributes can be applied to the specified labels and attributes such as the font and text color can be reflected to other languages labels. import english system menu (maintenance menu) chinese italian french note: windows xp (service pack3 or higher), vista or 7 is required for multi-language support. language a excel data language a and b excel data dual-language input in excel by translation companies and local companies multi-language messages for communications errors multi-language support support 42 languages and switch the language of the labels among up to 16 languages. unicode is supported and 42 asian and european languages can be combined in screens. also, it is possible to switch between up to 16 labels using the label switching function, so it is possible to support up to 16 languages in a single screen just by specifying the language to be displayed in each label. multi-language conversion has become much easier. the screen data in the source language is exported to a csv file and sent to a translation agency by e-mail for translation. later, the translated csv file is just imported to easily provide multi-language support. multi-language system messages. eight languages supported as standard feature the system program of NS-SERIES pts supports chinese and european languages. all eight languages are a standard feature, including chinese (traditional and simplified), spanish, italian, german, and french, in addition to the previous japanese and english. along with maintenance menus, messages for communications errors, communications settings, and screen transfers can be displayed in any of eight languages. maintenance can be performed in the desired language. the language can be easily set using the NS-SERIES pt or screen data. ns series support for 42 international languages
18 multifunction execution with one object easy on-screen setup with support software! touch on! touch delay: 0.5 to 15 s acceptance time: 0.5 to 30 s on! touch touch touc h ouch off! touch ouch to u ch ouch delay: 0.5 to 15 s multiple functions execute up to 32 functions with one multifunction object multifunction objects support write bit, write word, object control, and etc multifunction objects combine the functions of multiple objects into one object. multiple functions can be executed by pressing one button without using troublesome macros. setup is easy. for example, a setting can be made on-screen using the support software to turn on a bit to start a machine, set a value, and then change the screen. multifunction objects support four useful functions switches that do not immediately operate when touched can be easily made without ladder programming. turns on when the button is pressed for at least a specified time. button pressed relay status button pressed relay status button pressed relay status on delay double-press integration simultaneous pressing prohibited off delay turns on when the button is pressed twice within the specified time. turns off after a specified time lapses after the button is released. time the button is pressed. time the button is not pressed. does not turn on when the button is pressed at the same time as another button. execute multiple functions with one button. the screen changes. the word is set. the bit turns on. example:
19 design startup/operation maintenance ns-runtime features network system configuration ordering information specifications hand-held pt memory card log001.csv 04/06/04 10:00 log002.csv 04/06/05 10:00 log003.csv 04/06/06 10:00 log004.csv 04/06/07 10:00 log005.csv 04/06/08 10:00 log006.csv 04/06/09 10:00 log007.csv 04/06/10 10:00 information in the plc's format can be plotted moment-by-moment. d0000 d0001 d0002 x1 y1 x2 y2 x3 y3 (x1, y1) (x2, y2) (x3, y3) y x plc suffixes are automatically added to file names set in the cx-designer. logging data for each day (43,200 points) is saved in the memory card in csv format. the log data files in the memory card appear as shown below when the read file button is pressed. read file button it is possible to make a one-week log by automatically saving the data seven times. auto- matically saved (2) the display can be magnified. plentiful graphing functions data log graph (trend graph) up to 128 data can be collected in the cycle of 500ms. logging data is stored as a csv file in the memory card inserted in the NS-SERIES pt. logging data is stored as a csv file in the memory card mounted in the NS-SERIES pt. the data stored in the memory card can be read or deleted from the screen. a log can be saved automatically, without any programming, just by selecting the save the data periodically option in the data log setting window. continuous line function any position from the host (plc) can be plotted as a graph. a graph can be plotted in any position by specifying the x and y coordinates of the vertices. also, the graph can be moved on the screen by specifying the movements from the plc. line graph function the data logged by the plc can be displayed in overlapping graphs, so a device's operation can be compared for evaluation and analysis. in addition, up to 1,000 words of consecutive data can be displayed as a line graph, data can be displayed together, and any region can be magnified. (1) graphs can be superimposed.
20 80 100 30 c10004 c10005 c10006 80 100 30 dm0300 dm0302 dm0304 alarm value 1 alarm upper limit value 1 alarm lower limit value 1 80 100 30 dm0300 dm0302 dm0304 80 100 30 c10004 c10005 c10006 screen data security functions protect important screen data with a password. if password protection is set in the data transfer security settings when the screen data is designed, a password must be entered to download or upload the screen data, so important screen data can be protected. easier operation when combining sap library objects sap data can also be exchanged. sap data can be exchanged by checking the address of the sap data in the dialog box of the sap object pasted in the cx-designer and specifying that address as the transfer source address. multi-vendor support devices from multiple vendors are supported. data can be easily exchanged with plcs from other companies and modbus devices. device data transfer easy data exchange between the plc and components for example, temperature controller alarm values can be transferred to the dm area of the plc's cpu unit. no communications programming or macros are required. easy settings to make the settings, simply specify the device and addresses of the transfer source and transfer destination in the cx-designer. settings can be made using the same procedure as for setting the addresses for normal components. easy settings make the settings simply by specifying the addresses of the transfer source and transfer destination as well as the number of data items. ns temperature controller plc ns modbus device temperature controller plc from other company plc multi-vendor support if a password has been set, the password is required to transfer screen data (download or upload) with the memory card. download upload download upload security password a password between 4 and 64 characters long can be set. the download/upload will start if the user inputs the password that was set when the screen was designed. (password input will be disabled if the wrong password is input 3 times in a row.) ethernet/ip tags are not supported. cx-designer version 3.1 or higher is required. ns system version 8.2 or higher is required. note 1: note 2: cx-designer select device data transfer setting from the pt menu.
21 design startup/operation maintenance ns-runtime features network system configuration ordering information specifications hand-held pt ?cool? objects backgrounds, buttons, labels, message boxes, and other objects are also provided for various themes. aluminum water lighting game dot metal metalplate ns screen templates the cx-designer of version 3.5 or higher provides the palette to display objects and templates (scheduled for auto update in august 2012). refer to the next page for details of the palette. palette easy reading from palette address setting dialog box clean metal natural pop (default) even simpler templates can be read into the screen by just dragging and dropping thumbnails displayed on the palette. the template consisting of multiple screens allows multiple screens to be read by dragging and dropping it once. the address setting dialog box that is displayed to read templates is useful for changing addresses all at once. even more beautiful the refined templates enable you to use the ns series with the screens that have a sense of unity in design. three different types of templates besides default screens are provided. the design can be changed easily with "theme name" that is displayed when dragging and dropping. drag & drop new
22 new screen designer for ns series, cx-designer user-friendly screen creation without screen creation and ladder programming, the cx-designer screen design software is so easy-to-use that anyone can master it. quickly create the required screen by dragging and dropping objects. omron? s unified development environment lets you drastically reduce the work required to create screens. all addresses and comments can be managed using a single symbol table. shows a list of addresses, names, and comments used in project screen data. addresses, names, and i/o comments for the cx-programmer can also be imported. the project workspace enables the user to look through the entire project. drastically reduce the number of clicks in the project. the output window shows search results. screens you want to edit can be opened right away. perform screen management, such as copying or deleting screens, by simply right-clicking. reusing screens from other projects is easy with the cx-designer. settings for alarms, data logs, communications, and other functions can be easily accessed. just click on the object once to display or change properties. multiple objects can be selected to display and change shared properties all at once. in addition to addresses and i/o comments used in screen data, labels can also be used as search strings and the results can be displayed. note: the same type of project workspace and output window as in the cx-programmer are provided for the user interface. improved icons and help objects and templates can be selected easily from the palette. easy-to-use, well-designed, and super-beautiful objects and templates can be read into the screen by dragging and dropping. templates can be chosen from four different designs.
23 design startup/operation maintenance ns-runtime features network system configuration ordering information specifications hand-held pt new drag & drop change display color to blue. note. cx-designer version 3.5 or higher is required. palette switches and lamps are registered in the library. select a switch, lamp, or other object from the pull-down menu. you can register switches you created or other objects you often use in "user-defined". a template consists of multiple screens. multiple screens are pasted on the screen by dragging and dropping a thumbnail on the screen. library color setting display colors of objects registered in the library can be changed easily by selecting colors from pull-down menus. templates include design templates and device templates. design templates are the screen templates designed professionally. addresses can be changed with "address setting dialog box". template the import button allows new objects and templates to be added to the palette. import ?design template as well as sap (smart active parts), addresses on the screen are automatically updated by changing unit number of temperature controller or special i/o unit with "unit no dialog box". ?device template switches, lamps, and templates are registered in the palette. just drag and drop them on the new or existing screen to add. library and template tabs at the bottom left of the palette palette the palette appears on the right side of the screen when starting the cx-designer. templates are displayed in thumbnailed form. template parts list of switches and lamps is displayed. library
24 project b project a drag & drop project b project a drag & drop resources from another project can be easily reused by just selecting the screen or objects that you want to read and dragging and dropping it, so screens can be created intuitively. it is possible to import dxf files by dragging and dropping them. the files are read as a diagram, and so less capacity is used than with images. it is also easy to customize the diagram by changing the shape or color. the cx-designer and cx-programmer interconnects the test functions in the computer through the cx-simulator. the screens and ladder program checks are performed simultaneously, which significantly increases debugging efficiency. the cx-programmer also has a new button for integrated simulation. and, work efficiency is further improved with the ability to keep required work screens pinned on front and to zoom in or out as desired. reading another project's screens and objects reading cad files the screen data and ladder program can be checked simultaneously in the computer. example screen 1 select the screen that you want to read, drag it to the destination, and drop it. example screen 2 select the part that you want to read, drag it to the destination, and drop it. cx-one version 2.0 on computer ladder program touch panel interactive ladder prog el ladder program window touch panel screen interactive
25 design startup/operation maintenance ns-runtime features network system configuration ordering information specifications hand-held pt the i/o comment is used as the label. (2) check the comment then drag-and-drop the symbol from the symbol table to the property list. drag & drop drag & drop drag & drop reading the symbol table the symbol table created in the cx-programmer during ladder programming can be read into the cx-designer by dragging and dropping, so it isn't necessary to manually data such as input addresses and i/o comments. tags (i.e., network symbols) can also be read into the cx-designer. the symbol table read from the cx-programmer can be directly dragged and dropped to the touch switch and lamp. if use i/o comment is selected in advance for the use symbol text as label, the i/o comments are automati- cally used as labels when addresses are dragged and dropped from the symbol table. (if use symbol names is selected, the symbol names are used as the labels.) version 8.0 or higher of the cx-programmer support tags (i.e., network symbols). (1) create a switch on the screen. (3) allocations for buttons and lamps can also be checked on the screen using comments imported from the cx-programmer. example of easy address allocation note: cx-programmer's symbol table cx-designer's symbol table the cx-programmer's symbol table can be dragged and dropped! example of reading the symbol table example of reading i/o comments
26 console camera console rgb camera equipment and workpiece movements can also be displayed in beautiful video ns-ca001 video input unit four video inputs or ccd cameras can be connected and up to four images can be displayed simultaneously if the image size is 320x240 pixels. the ns-ca001 cannot be used with the ns5 or the ns15. ns-ca002 rgb/video input unit there is an analog rgb input terminal in addition to the two video input terminals. either of the video signals or the analog rgb signal can be displayed on the NS-SERIES pt. the ns-ca002 cannot be used with the ns5. 260,000-color video display the ns15 screen (xga) can be displayed on an on-site display that has rgb inputs. the ns screen is seen by another monitor. analog rgb output also compatible with omron vision sensors. note: only ns15 video input cannot be used with the ns15. only rgb input can be used. note:
27 design startup/operation maintenance ns-runtime features network system configuration ordering information specifications hand-held pt level 4 level 3 level 2 level 1 level 5 high low screens, bitmaps, text, recipe data you can partially replace text and pictures from your computer. ftp (file transfer protocol) has been added! texts, lists, and recipes can be replaced with the put/get command from your computer! you can even replace bmp files from your computer easily. operator access rights and the operating format can be set to one of five password levels. each operator can be given one of 5 password levels using the user security (level authentication) function. a password level can be set for each object, so various objects can be made inoperable or hidden based on the operator's access level. ftp function user security functions ns5 color-type models (sq/tq models), ns8 models, ns10 models, ns12 models, ns15 models with led backlight are newly released. * ns with led backlight led backlight allows backlight brightness adjustment of up to 32 levels. the brightness can be adjusted from the operation screens, and the run indicator changes its luminance according to the settings of the backlight brightness; it is favorable for ship and vessel applications. * lotno.15z0 or later of ns5 color-type models, lotno.28x1 or later of ns8 models, lotno.11y1 or later of ns10 models, lotno.14z1 or later of ns12 models, lotno.31114k or later of ns15 models. operator passwords are managed in 5 levels. passwords can be up to 16 characters long and the access rights increase as the level number increases. the operator cannot manipulate objects with a password level (authentication level) higher than the operator's login level. new 32-level adjustment conventional three-level adjustment
28 ns cx-designer cx-programmer note: communications across network layers can be performed. usb relay cable (ip65 oil-proof type) (sold separately: ns-usbext-1m) commercially available usb cable spma can be used in cs/cj-series plcs with lot number 030201 or later. spma via a plc is not supported when a cp-series plc is connected. (spma via an NS-SERIES pt is supported with a cp-series plc.) cx-programmer version 8.2 and higher support automatic online connection via the pt. ns system version 8.2 or higher is required. note 1: note 2: note 3: single port multi access (spma) transfer ladder program data to the plc via the pt. perform online editing via the pt. transfer screen data via the plc. comparison the on-site ns screen can be compared with the computer screen. new pt transfer compare comparison result usb connection is supported only for cj2 plcs. note: the ladder program can be transferred. the ladder program can be transferred. a search is automatically made for the plcs connected to the pt and the results are displayed using the automatic online connection function in the cx-programmer. just select a plc from the list to connect. this function is also supported for plcs over network layers. use a usb relay cable to enable performing maintenance from in front of the control panel. using a usb relay cable greatly improves debugging at equipment startup. easy automatic connection cx-programmer automatic search plcs registered to the pt are automatically searched for. make the connection simply by selecting from the plc list. plc ladder program ladder program usb or ethernet serial connection (1: n nt link only) ethernet controller link ns cx-programmer ethernet or controller link computer (serial) plc (ethernet or controller link) NS-SERIES pt computer (serial/usb) NS-SERIES pt (ethernet) plc (ethernet or controller link) plc the comparison function of the cx-designer enables the following comparison. cx-designer project project in the computer cx-designer project ns project plc ns ethernet or controller link serial usb/serial or ethernet (see note.) cx-designer screen data screen data screen data keep connected. keep connected. same in screen different in screen screen added screen deleted same different added deleted comparison
29 design startup/operation maintenance ns-runtime features network system configuration ordering information specifications hand-held pt cs/cj/cp-series plc data trace switch directly from the user screen to the log operation display screen. a comment of up to 32 characters can be set and displayed for each operation to provide easy-to-understand information about what type of operation was performed. m the user screen n di sp l ay screen . there are differences between this data trace function and the cx-programmer's data trace function. refer to the NS-SERIES programmable terminal programming manual (cat. no. v073) for details. the plc data trace function cannot be used with the 5.7-inch model. the plc data trace function is not supported for connection with a cp1e plc. note 1: note 2: note 3: plc data trace the plc data trace function can be used without a computer. the plc data trace function is built into the pt in addition to the ladder monitor and device monitor. a bit's status and operation can be viewed in a time chart just by setting the desired plc bit's address in the pt. it is also now possible to display word data, save data in csv files, and save time chart screens in bmp files. operating log what was touched when? can be recorded. functionality has been improved with the addition of a log to record operators? use of the panels. it is now possible to record and display the time, date, and operation details for buttons (i.e., hardware switches) pressed on the control panel in addition to operations on the touch panel. the operation log can be saved in a csv file on a memory card mounted in the NS-SERIES pt. operat_080520_ 173000.csv operat_080521_ 173000.csv operat_080522_ 173000.csv for example, with a control panel comprised of the NS-SERIES pt, hardware switches, and an emergency stop button, you can even record and display operation of the emergency stop button. the files can be opened in excel. multiple operation log files can be saved on a memory card with date and time data. memory card
30 found it! alarm ladder monitor the ladder program can be monitored without a computer. so no extra work to show i/o comments also meets the requirements of users who need to display devices onsite easy checking the alarm bit and shortens searching time. when an alarm occurs, touch the message to automatically search for the alarm bit (output bit) for the alarm. this enables you to quickly check the alarm address and investigate why the bit turned on. read i/o comments directly from the plc. i/o comments do not have to be stored in a memory card. switch box function the operator can check the plc status by displaying just the i/o comments and status. device monitor function displays the device's contents, allowing settings to be input and checked and making startup operations more efficient. ladder programs with i/o comments can be monitored on the pt's screen and the ladder program can also be edited with the programming console function. switch box function device monitor function operation screen cs/cj/cp-series plc select read i/o comment reading from the menu. the i/o comments are displayed.
31 design startup/operation maintenance ns-runtime features network system configuration ordering information specifications hand-held pt yes, the problem is here! 4. forced on check and change i/o while you view the ladder diagram on the i/o monitor display and change the present value by specifying the address. it is also possible to force-set/reset bits with the i/o monitor. force-setting and force-resetting are possible locations that have been force-set are displayed in pink and can be checked at a glance. 1.select the input bit for which the output will be forced on. ?find back?, ?find next?, useful function supported by the NS-SERIES. reduced time to investigate which output or input is causing the problem. return to the previous search position. find the output from the input bit or find the input bit from the output at the cursor. find the address at specified by the cursor. ?b? key ?space? key ?n? key double-click function operation with NS-SERIES pt. cx-programmer next back back change ubl e-c li n with ns - series pt. n e xt b ac k i ck k 2. is this input the cause? what output corresponds to this input? 1. why is this output not turning on? 3. why is this output not turning on? 5. there?s no problem with input cio 21.00. let?s go back to the previous program section. 4. which of these two inputs is the cause? let?s look at cio 21.00 first. 6. so is it input cio 21.01 after all? select the address by touching the panel. select the forced set option and then press the update button. 2. 3. minor changes in values of timers or counters can be made without support software. make the selection with the i/o monitor by touching the screen. changing the present value of the address selected with the change value button the ladder monitor function is not supported by the 5.7-inch models. note:
32 to maintenance screen to maintenance screen max 3840pixel max 2400pixel ns-nsrcl (ns-runtime) machine monitoring in an office environment. there is no need to create complex host applications. moreover, when an alarm occurs, a pdf file can be displayed as maintenance information. ns series screens can be reused on the computer, and screens can be also newly created independently of touch panels at the production site. wide screen computer output can be displayed on another wide-screen monitor. xga (1,024 x 768 dots) and up to a a maximum screen size of 3,840 x 2,400 is supported. alarms occurring in devices or the line can be monitored. data logger log large amounts of data using a personal computer. data can be logged through background processing, with up to 160,000 points stored in one file. the logged data is stored in csv format, and data can be displayed on data log graphs. data can be logged for approximately 7.4 days, assuming data is logged every two seconds for 12 hours a day. by using automatic file saving, data logging can be continued even longer than 7.4 days. achieve machine/line monitoring and data logging on your office computer. ethernet displaying maintenance information (pdf file) machine viewer monitoring device alarms ns-runtime example: 160,000 points stored data csv format monitor output the resolution that can be displayed depends on the computer. an input function for displaying the computer screen is required at the display monitor. note: to ma inten ance screen to maintenance screen to maintenance screen to maintenance screen
33 design startup/operation maintenance ns-runtime features network system configuration ordering information specifications hand-held pt if the screen data is converted for the ns series, NS-SERIES pt system versions must be 8.1 or earlier. the screen data of system version 8.2 can not be converted for the ns-runtime. do not use this product for 24-hour operation in an fa environment. omron shall not be responsible if the computer or application does not operate properly due to noise or other causes. omron shall not be responsible for any problems that may be caused by any applications other than omron products. note 1: note 2: checking machine data or switching processes from a host computer is easy. parameter groups in the plc can be transferred together to a computer, and the transferred data can be checked and edited in csv format, e.g., using excel. the edited data can then be transferred together back to the plc. easy installation to get started, just install the ns-runtime in the computer and place the screen data in the applicable folder. ns/nsj-series screens and ns-runtime screens can all be managed using one single tool. application startup function user applications can be started from ns-runtime. applications can be started simply by pressing buttons on the screen. user application ns-runtime recipe handling screen designer: cx-designer (cx-one) for example, to start an application by pressing a button? use the exec( ) macro. the ns-runtime will operate in a computer environment even if the cx-designer installed is not installed. the hardware key (usb dongle) that is supplied with the ns-runtime is required for operation. note: as much as possible, keep applications closed that are not required for operation. note: example: exec("c:programfiles\micros..\excel.exec:\..\ yyyytest2.xls?..); started screen data to plc recipe data csv format ns-runtime o n te d
34 nsh5 series a hand-held version of the ns5 is now available to perform operations at the production site. the NS-SERIES pt's have a complete set of functions that can be used at the production site, such as the sap library, multi-language support, and programming console functions. precautions for emergency stop switches when using a hand-held nsh5 that will be installed and removed from a control panel or removable box, always use the specified stop switch (gray/nsh5-sqg10b-v2) to conform to safety standards (en 60204-1). function switches emergency stop switch. water resistance to ip65 pt and cable sold separately options removable box a separate external circuit is not required because the removable box has been configured so that the emergency stop switch line will not turn off (i.e., so that the emergency stop circuit will operate) even when the nsh5 is removed. visor use when the nsh5 is in direct sunlight. mounting bracket use to attach the nsh5 to a control panel. 3-position enable switch memory card interface and usb slave connector. use the ten functions switches. f1, f2, f6, f7: wired outputs f3 to f5, f8 to f10: communications outputs increased safety with dpst-no structure (wired outputs). select the cable according to the application (rs-232c/rs-422a). connector-loose wires, ul connector, 3 m or 10 m. the water-resistant structure is equivalent to ip65 on all surfaces. the pt may not be suitable for use in environments with long-term water exposure. 3pst-nc structure dpst-nc: increase safety (wired outputs). spst-nc: input to internal nsh5 memory, output to a lamp for emergency stop switch operation, or output via communications, e.g., to a plc. easily transfer screens or save logs at high speed using a usb connection.
1 programmable terminals ns series even simpler equipment operat ion with outstanding synergy. features ? 5.7 to 12.1 inch sizes are available. ? a hand-held version of the ns5 is now available to perform operations at the production site. the NS-SERIES pt's have a complete set of functions that can be used at the production site. ? the smart active parts( sap library) makes it easy to conne ct to omron plcs and components, omron provides a development environment that requires with no programming and no screen designing. ? when an error occurs in a unit in the omron plcs, the troubleshoote r sap library provides an easy-to- understand explanation of the cause of the error as well as the countermeasures. ? ladder monitor come as a standard feature. the ladder program can be monitored onsite without a laptop! ladder monitor lets you monitor plc program status, sear ch for addresses or instructions, monitor multiple i/o points, and much more. ? provides the fa integrated tool package "cx-one" for a screen design software integrated simulation come as a standard feature. the integrated simulation function si mulates ladder programs and screen data simultaneously even without the actual hardware. ? screens support 42 languages and the support software supports eight. system messages can be displayed in eight languages. ? single port multi access (spma) come as a standard feature. the ladder program and screen data can be transferred from a single port! ? connectable plcs and devices appear one after another. has become connectable with the plcs of mitsubishi electric corporation and the inverters of omron corporation. sysmac is a trademark or registered trademark of omron corporat ion in japan and other countries for omron factory automation pr oducts. windows is registered trademarks of microsoft corporation in the usa and other countries. ethercat is a registered trademark and patented technol ogy, licensed by beckhoff au tomation gmbh, germany. other company names and product names in this document are the trademarks or registered trademarks of their respective companie s. 5.7 inches color tft 10.4 inches 15 inches 12.1 inches 8.4 inches stn monochrome color tft color tft color tft color tft
ns series 2 network provides serial nt link comm unications supporting both 1:1 and 1:n connections. the nt link has more efficient communications t han host link and its capabilities are especially apparent in applications with multiple pts connect to the plc. the NS-SERIES pts can also s upport communications with multiple plcs and multiple NS-SERIES pts through controller link and ethernet connections, so the network c an be configured freely to match the requirements and scale of the application. in addition, using the ns-runtime makes it possible to monitor machine status and log data from the host. configuration of cj2 series, nj series and nx series if an ethernet-compatible NS-SERIES pt is us ed, the pt can connect to a controller with built-in ethernet/ip and an option unit is not needed to connect at the pt. 1 ethernet/ip connection (tag accesses) n s-series pt n s-series pt cs/cj-series plc n s-series pt cs/cj-series plc cs/cj-series plc n s-series pt cs/cj-series plc personal comp uter softw are for machine monitoring and data logging 1 ethern et/ip (tag access) 3 controller link 2 serial connection 2 serial connection 5 connections across netw ork le v els (sold separately) [example NS-SERIES network configuration] 4 ethern et/ip, ethernet n s-series pt n s-series pt controller controller controller personal comp uter
ns series 3 configuration of cs series, cj series and cp series 1:1 nt link or host link the pt can be connected to an omron controller link net work by mounting a controller link interface unit. if an ethernet-compatible NS-SERIES pt is used, the pt can connect to a plc with an ethernet unit and an option unit is not needed to connect at the pt. the NS-SERIES pts can connect to a variety of devices in the network, through as many as 3 network levels. for example, if sap (smart active parts) are being used, an ns -series pt connected by ethernet can be used to monitor the infor mation in a plc connected through controller li nk as well as the information in the devicenet slaves connected to that plc. 2 serial connection 3 controller link connection 4 ethernet/ip or ethernet connection 5 connections over network levels plc NS-SERIES pt NS-SERIES pt NS-SERIES pt NS-SERIES pt NS-SERIES pt plc plc ns-al002 converter (converts between rs-232c and rs-422a.) plc ns:plc = 1:1 ns:plc = 1:2 ns:plc ratio = 8:1 max. connecting with the plc through port a or port b up to 8 NS-SERIES pts can be connected to each of the plc's rs-232c/rs-422a ports. 1:n nt link ns-clk21 if a controller link connection is used, data links can be set between plcs and multiple plcs can be monitored/set from the NS-SERIES pt's screen. 2 mbps (500 m max.) 1 mbps (800 m max.) 500 kbps (1 km max.) ns series pt plc plc plc baud rate max. number of nodes: 32 nodes ns series pt ns series pt plc plc plc personal computer devicenet ns series pt seamless and program-less seamless and program-less ns series pt ethernet controller link plc plc plc
ns series 4 system configuration ns5/ns8/ns10/ns12/ns15 temperature controller omron plc rs-232c rs-422a memory link connection compoway/f connection modbu s (memobus)-rtu connection ethernet wireless ethernet rs-232c ethernet usb usb omron memory card rs-422a conversion unit cj1w-cif11 ns-al002 note: a conversion unit is not required to connect to the rs-422a/485 serial interface of the ns15. omron plc omron plc omron plc bar code reader recommended: omron v520-rh21-6 personal computer micro-computer board, personal computer, etc. ethernet port usb slave usb master rs-232c port rs-232c port pt-to-plc connecting cable xw2z-200t (length: 2 m) xw2z-500t (length: 5 m) standard usb cable commercially available. standard usb cable commercially available. standard usb cable commercially available. we70 we70 screen transfer cable xw2z-s002 (length: 2 m) screen transfer cable xw2z-s002 (length: 2 m) usb serial conversion cable cs1w-cif31 memory card interface personal computer personal computer usb pictbridge-compatible printer pictbridge inverter ethern et/ip omron controller
ns series 5 expansion bus interface multi-vendor plc vision sensor personal computer controller link rgb output expansion bu s interface controller link interface unit ns-clk21 ntsc/pal video input unit ns-ca001 ntsc/pal rgb/video input unit ns-ca002 any one of the following units can b e mounted to the expansion bu s interface. note: v ideo input units and rgb v ideo input units cannot be used with some models. rs-232c computer link unit rs-422a/485 (see note.) screen transfer ca b le xw2z-s002 (length: 2 m) rs-232c port rs-232c port function extension board or mitsubishi fx-series plc commu nications adapter mitsub ishi fx-series plc mitsub ishi a-series plc computer link mod ule yo k o g a was fa-m3(r) series computer link mod ule yokoga was fa-m3(r) series serial comm unications unit mitsub ishi qna-series plc serial comm unications unit mitsub ishi q-series plc serial comm unications unit mitsub ishi qna-series plc serial comm unications unit mitsub ishi q-series plc serial comm unications module yaska wa mp-series plc serial comm unications module yaska wa mp-series plc rockwell (allen-bradley) plc-5-series plc modbu s device (rtu mode) rockwell (allen-bradley) slc500/micrologix/controllogix/ compactlogix/plc-5-series plc modbu s device (rtu mode) mitsubishi a-series plc mitsub ishi fx-series plc function extension board or mitsubishi fx-series plc commu nications adapter simatic s7 hmi adapter siemens s7-300-series plc computer link unit rs-422a conversion unit cj1w-cif11 ns-al002 note: a conversion unit is not required to connect to the rs-422a/485 serial interface of the ns15. note: whether an rs-422a or rs-4 8 5 connection is supported depends on the device that you are connecting to. for details, refer to the connectable devi ces page or NS-SERIES programmable termin als host connection manual multivendor connection (cat. v 092).
ns series 6 nsh5 hand-held pt removable box rs-232c connecting cable for the nsh5 nsh5-232cn-3m (length: 3 m) rs-232c connecting cable for the nsh5 nsh5-232cn-10m (length: 10 m) rs-232c cable nsh5 (see note.) removable box control panel rs-232c connection (cable length: 3 or 10 m) rs-422a connection (total cable length: 500 m max.) system configuration (removable box connected) plc usb slave memory card interface omron memory card nsh5 pt nsh5 pt ul-listed cables removable box connected usb rs-232c connecting cable for the nsh5 nsh5-232cw-3m (length: 3 m) rs-232c connecting cable for the nsh5 nsh5-232cw-10m (length: 10 m) rs-232c cable rs-232c rs-422a rs-422a connecting cable for the nsh5 nsh5-422cw-10m (length: 10 m) rs-422a cable rs-232c connecting cable for the nsh5 nsh5-232ul-3m (length: 3 m) rs-232c connecting cable for the nsh5 nsh5-232ul-10m (length: 10 m) rs-232c cable rs-232c rs-422a rs-422a rs-422a connecting cable for the nsh5 nsh5-422ul-10m (length: 10 m) rs-422a cable personal computer commercially available usb cable. usb slave memory card interface usb omron memory card personal computer commercially available usb cable. plc plc plc plc plc up to 15 removable boxes can be connected. up to eight nsh5s can be connected at a time. note: before removing the nsh5 from the removable box, be sure to first turn off the power supply key on the removable box.
ns series 7 ordering information international standards ? the standards are availabled as fo llows: u: ul, u1: ul (class i division 2 products for hazardous locations), c: csa, uc: culus , uc1: culus (class i division 2 products for haza rdous locations), cu: cul, n: nk, l: lloyd, and ce: ec directives. ? contact your omron representative for further det ails and applicable condit ions for these standards. programmable terminals *1. as of july 2008, the image memory has been increased to 60 mb. *2. lot no. 15z0 or later of ns5 color-type models, lot no. 28x1 or later of ns8 models, lot no. 11y1 or later of ns10 models, lot no. 14z1 or later of ns12 models, lotno.31114k or later of ns15 models. ns-runtime note: a hardware key (usb dongle) is required for ns-runtime operation. system requirements product name specifications model standards effective display area number of dots ethernet case color ns5-v2 *1 5.7-inch *2 tft color led backlight 320 240 dots no ivory ns5-sq10-v2 uc1, ce, n, l, ul type4 black ns5-sq10b-v2 yes ivory ns5-sq11-v2 black ns5-sq11b-v2 5.7-inch *2 high-luminance tft color led backlight no ivory ns5-tq10-v2 black ns5-tq10b-v2 yes ivory ns5-tq11-v2 black ns5-tq11b-v2 ns8-v2 8.4-inch *2 tft led backlight 640 480 dots no ivory ns8-tv00-v2 uc1, ce, n, l black ns8-tv00b-v2 yes ivory ns8-tv01-v2 black ns8-tv01b-v2 ns10-v2 10.4-inch *2 tft led backlight 640 480 dots no ivory ns10-tv00-v2 uc1, ce, n, l, ul type4 black ns10-tv00b-v2 yes ivory ns10-tv01-v2 black ns10-tv01b-v2 ns12-v2 12.1-inch *2 tft led backlight 800 600 dots no ivory ns12-ts00-v2 black ns12-ts00b-v2 yes ivory ns12-ts01-v2 black ns12-ts01b-v2 ns15-v2 15-inch tft 1,024 768 dots yes silver ns15-tx01s-v2 black ns15-tx01b-v2 nsh5-v2 *1 hand-held 5.7-inch tft 320 240 dots no black (emergency stop button: red) nsh5-sqr10b-v2 uc, ce black (stop button: gray) nsh5-sqg10b-v2 product name specifications media model standards ns-runtime ns-runtime installer, pdf manual, hardware key (see note.) 1license cd ns-nsrcl1 --- 3 licenses ns-nsrcl3 10 licenses ns-nsrcl10 item specifications os windows xp (service pack 3 or higher), vista, 7 or 8 (support 64-bit version for windows 7 and windows 8.) cpu celeron, 1.3 ghz or higher (recommended) memory size hdd: 50 mb min., ram: 512 mb min. (windows 7: 1 gb min.). 50 mb is required for the runtime alone. (an additional 280 mb is required if cx-server is not already installed.)
ns series 8 software how to select required support software for your controller the required support software depends on the c ontroller to connect. please check the fo llowing table when purchasing the suppor t software. fa integrated tool package cx-one *1. multi licenses are avail able for the cx-one (3, 10, 30, or 50 licenses). *2. the cx-one is also available on cd (cxone-al @@ c- v 4). automation software sysmac studio please purchase a d v d and required number of licens es the first time you purchase the sysmac studio. d v ds and licenses are available individually. each model of licenses does not include any d v d. note: to connect the nj5 controll er, ns system version 8 .5 or higher is required. cx-designer version 3.3 or higher is al so required. to connect the nj1/nj3 contro ller, ns system version 8 .61 or higher is required. cx-designer version 3.4 or higher is also required. to connect the nx7 controller, ns system version 8 .9 or higher is required. cx-designer version 3.64 or higher is also required. * multi licenses are available for the sysm ac studio (3, 10, 30, or 50 licenses). item omron plc system omron machine automation controller system controller cs, cj, cp, and other series nj-series and nx-series programmable terminals NS-SERIES NS-SERIES with an ethernet port software fa integrated tool package cx-one automation software sysmac studio product name model standards specifications number of licenses media fa integrated tool package cx-one ver.4. @ the cx-one is a comprehensive software package that integrates support software for omron plcs and components. cx-one runs on the following os. w indows xp (service pack 3 or higher, 32-bit version) / w indows v ista (32-bit/ 64-bit version) / w indows 7 (32-bit/64-bit version) / w indows 8 (32-bit/64-bit version) / w indows 8 .1 (32-bit/64-bit version) cx-one v ersion 4. @ includes cx-designer v er.3. @ . for details, refer to the cx-one catalog (cat. no. r134) license *1 d v d *2 cxone-al01d-v4 --- product name specifications model standards number of licenses media sysmac studio standard edition ver.1. @ the sysmac studio provides an integrated development environment to set up, program, debug, and maintain nj/nx series controllers and other machine automation controllers, as well as ethercat slaves. sysmac studio runs on the following os. w indows xp (service pack 3 or higher, 32-bit version) / w indows v ista (32-bit version) / w indows 7 (32-bit/64-bit version) / w indows 8 (32-bit/64-bit version) / w indows 8 .1 (32-bit/64-bit version) the sysmac studio standard edition d v d includes support software to set up ethernet/ip units, devicenet slaves, serial communications units, and support software for creating screens on hmis (cx-designer). for details, refer to the sysmac integrated catalogue (p072). - (media only) d v d sysmac-se200d --- 1 license* --- sysmac-se201l ---
ns series 9 cable *1. use a standard usb type a male to type b type male cable to c onnect the ns series pt to a personal computer (cx-designer). use a standard usb cable to connect the ns series pt to a pictbr idge-compatible printer. usb cable type depends on the printer. *2. to connect the ns series pt to nj series controller, us ing a commercially available 10/ 100-base-tx twisted-pair cable. for detail, refer to the ns series setup manual (cat. no. v08 3). product name specifications model standards cable *1 screen transfer cable for dos/ v (cx-designer ? pt) length: 2 m xw2z-s002 --- usb-serial conversion cable length: 0.5 m cs1w-cif31 n usb relay cable length: 1 m ns-usbext-1m --- nsh5 cables rs-422a cable (loose wires + d-sub 9-pin) length: 10 m nsh5-422cw-10m rs-232c cable (loose wires + d-sub 9-pin) length: 3 m nsh5-232cw-3m rs-232c cable (loose wires + d-sub 9-pin) length: 10 m nsh5-232cw-10m ul-compliant nsh5 cable rs-422a cable (loose wires) length: 10 m nsh5-422ul-10m cu rs-232c cable (loose wires + relay cable) length: 3 m nsh5-232ul-3m rs-232c cable (loose wires + relay cable) length: 10 m nsh5-232ul-10m pt-to-plc connecting cable *2 pt connection: 9 pins plc connection: 9 pins length: 2 m xw2z-200t --- length: 5 m xw2z-500t pt connection: 9 pins plc peripheral port length: 2 m xw2z-200t-2 length: 5 m xw2z-500t-2 nsh5 removable box cable rs-232c cable (connectors) length: 3 m nsh5-232cn-3m length: 10 m nsh5-232cn-10m nsh5 removable box --- nsh5-al001 nsh5 wall-mounting bracket --- nsh5-att02 nsh5 visor --- nsh5-att01
ns series 10 options *1. one screen cannot display tw o video inputs simultaneously. *2. a chemical-resistant cover (nt30-kba01) is available only for the ns5. product name specifications model standards video input unit inputs: 4 channels signal type: ntsc/pal ns-ca001 uc1, ce input channels: 2 video channels and 1 rgb channel *1 signal type: ntsc/pal ns-ca002 controller link interface unit for controller link communications ns-clk21 uc1, ce rs-422a adapter transmission distance: 500 m total length note: use this model when connecting pt models without a v @ suffix. note: pt models with the v @ suffix can also be connected. ns-al002 --- transmission distance: 50 m total length note: only pt models with a suffix of v @ are connectable. use the ns-al002 to connect models without a v @ suffix. cj1w-cif11 uc1, n, l, ce sheet/cover *2 anti-reflection sheets (5 surface sheets) ns15 ns15-kba04 --- ns12/10 ns12-kba04 ns8 ns7-kba04 ns5 nt30-kba04 protective covers (5 pack) (anti-reflection coating) ns12/10 ns12-kba05 ns8 ns7-kba05 ns5 nt31c-kba05 protective covers (1 cover included) (transparent) ns15 ns15-kba05n protective covers (5 covers included) (transparent) ns12/10 ns12-kba05n ns8 ns7-kba05n ns5 nt31c-kba05n attachment nt625c/631/631c series to ns12/10 series ns12-att01 nt625c/631/631c series to ns12/ns10 series (black) ns12-att01b nt610c series to ns12/10 series ns12-att02 nt620s/620c/600s series to ns8 series ns8-att01 nt600m/600g/610g/612g series to ns8 series ns8-att02 memory card 128 mb hmc-ef183 256 mb hmc-ef283 512 mb hmc-ef583 memory card adapter --- hmc-ap001 ce replacement battery battery life: 5 years (at 25 c) cj1w-bat01 --- bar code reader ccd handheld bar code reader (rs-232c interface) v520-rh21-6
ns series 11 general specifications ns5/ns8/ns10/ns12/ns15 *1. operate the pt within the temperature and humidity ranges shown in the right diagram. *2. support for ns5, ns10, ns12 and ns15. nsh5 hand-held pt series ns5-v2 ns8-v2 ns10-v2 ns12-v2 ns15-v2 rated power supply voltage 24 vdc allowable voltage range 20.4 to 27.6 vdc (24 vdc 15%) power consumption 15 w max. 25 w max. 45 w max. ambient operating temperature 0 to 50 c (see note on the next page.) note: the ambient operating temperature is subject to the following restrictions according to the mounting angle. mounting angle of 0 to 30 to the horizontal: ? when no expansion units are mounted, the operating temperature range is 0 to 45 c. ? when a video input unit or a controller link interface unit is mounted, the ambient operating temperature is 0 to 35 c. mounting angle of 30 to 90 to the horizontal: operating temperature range of 0 to 50 c storage temperature ? 20 to 60 c *1 ambient operating humidity 35 to 85% (0 to 40 c), 35 to 60% (40 to 50 c) (with no condensation) operating environment no corrosive gases. noise immunity conforms to iec61000-4-4, 2 kv (power lines). vibration resistance (during operation) 10 to 57 hz, 0.075 mm amplitude, 57 to 150 hz, 9.8 m/s 2 30 min each in x, y, and z directions 5 to 8.4 hz, 3.5 mm single amplitude, 8.4 to 150 hz, 9.8 m/s 2 10 min times each in x, y, and z directions shock resistance (during operation) 147 m/s 2 3 times each in direction of x, y, and z weight 1.0 kg max. 2.0 kg max. 2.3 kg max. 2.5 kg max. 4.2 kg max. degree of protection front operating panel: ip65 oil-proof type and nema4 ul type 4. *2 note: may not be applicable in locations with long-term exposure to oil. ground ground to 100 or less. battery life 5 years (at 25 c): replace battery within 5 days after the battery runs low (indicator lights orange). applicable standards certified for conformance to ul 508, ul 1604, emc directive, nk, and lr standards. series nsh5-v2 type 5.7-inch color tft (hand-held version) case color black built-in ethernet port no model nsh5-sqr10b-v2 (emergency stop button: red) nsh5-sqg10b-v2 (stop button: gray) rated power supply voltage 24 vdc allowable voltage range 20.4 to 27.6 vdc (24 vdc 15%) power consumption 10 w max. ambient operating temperature 0 to 40 c storage temperature ? 20 to 60 c ambient operating humidity 35% to 85% (0 to 40 c) with no condensation operating environment no corrosive gases. noise immunity common mode: 1,000 vp-p (between power supply terminals and panel) normal mode: 300 vp-p pulse width: 100 ns to 1 s, rise time: 1-ns pulse vibration resistance (during operation) 10 to 57 hz, 0.075 mm amplitude, 57 to 150 hz, 9.8 m/s 2 30 min each in x, y, and z directions shock resistance (during operation) 147 m/s 2 3 times each in direction of x, y, and z weight 1 kg max. degree of protection equivalent to ip65. ground ground to 100 or less. battery life 5 years (at 25 c): replace battery within 5 days after the battery runs low (indicator lights orange). applicable standards certified for conformance to ul 508, emc directive, and en 60204-1. 90 display s u rface 30 horizontal 0 60 50 40 30 20 10 0 temperat ure (c) temperat ure (c) humidity (%rh) 8 07060 50 4030 20 100 ?20 10% 20% 35% 40% 60% 80% 95% storage operation
ns series 12 performance/specifications ns5 *1. ns5-tq series (high luminance tft) luminance is better than that of ns5-sq series by about 110 cd/m 2 . *2. contact your nearest omron represent ative to replace the backlight. *3. this is the estimated time before bri ghtness is reduced by half at room temperat ure and humidity. it is not a guaranteed value. the service life will be dramatically shortened if pt is used at low temperatures. for example, using the pt at temperatures of 0 c will reduce the service life to approximately 10,000 hours (reference value). *4. lot no. 15z0 or later of ns5 models. *5. this function does not indicate that the service life has been reached. it detects when the backl ight is not lit due to a disconnection or other errors. backlight error detection indicates that all backlights (2) are off. series ns5-v2 model ns5-sq10-v2 ns5-sq11-v2 ns5-sq10b-v2 ns5-sq11b-v2 ns5-tq10-v2 ns5-tq11-v2 ns5-tq10b-v2 ns5-tq11b-v2 built-in ethernet port no yes no yes no yes no yes case color ivory black ivory black display device tft color lcd color high-luminance tft *1 effective display area width 117.2 height 88.4 mm (5.7 inches) display colors 256 colors number of dots 320 dot horizontal 240 dot vertical view angle left/right: 80 , top: 80 , bottom: 60 *5 screen data capacity 60 mbytes image data (bmp or jpg images) 32,768 colors memory card supported ladder monitor function not supported video input unit support not supported controller link interface unit (wired) support not supported backlight *2 service life * 3 75,000 hours min. brightness adjustment three-level or 32-level brightness adjustment from the touch panel screen. * 4 backlight error detection *5 error is detected autom atically, and the run indicator flashes green as notification. touch panel (matrix type) method matrix resistive membrane number of switches/ resolution 300 (20 horizontal 15 vertical) 16 16 dots for each switch input pressure-sensitive service life 1,000,000 touch operations. display text labels can be specified in cx-designer. font , style, and size can be specified. numerals, alarms, and character strings scalable gothic: magnification: 6 to 255 points rough: magnification: 1 1, 1 2, 2 1, 2 2, 3 3, 4 4, 8 8 standard: magnification: 1 1, 1 2, 2 1, 2 2, 3 3, 4 4, 8 8 fine: magnification: 1 1, 1 2, 2 1, 2 2, 3 3, 4 4, 8 8 7-segment display: can display only numerals, dates, and times. supported languages (42 languages) scalable gothic, rough, standard, and fine can be used for 42 languages. japanese, simplified chinese, traditional chinese, korean, englis h, french, german, italian, portuguese, spain, swedish, dutch, finnish, norwegian, basque, catalan, danish, albanian, croati an, czech, hungarian, polish, romanian, slovak, slovenian, bulgarian, belarusian, russian, serbian, macedonian, ukrainian, georgian, icelandic, afrikaans, faroese, indonesian, greek, turkish, estonian, latvian, lithuanian, thai (supported only with scalable gothic font) text attributes color 256 colors font style (only when vector font is specified) bold or italic vertical alignment top, center, or bottom horizontal alignment left-justified, centered, or right-justified flicker objects supporting flicker functional objects: select from up to 10 types of registered flicker settings. the flicker speed and flicker range can be set. fixed objects: select from three flicker types. numeral units and scale settings 1.000 max. alarm/event settings 5,000 max. expansion interface for expansion interface units
ns series 13 ns8/ns10/ns12/ns15 *1. contact your nearest omron repres entative to replace the backlight. *2. this is the estimated time bef ore brightness is reduced by half at room temperature and humidity. it is not a guaranteed value. the service life will be dramatical ly shortened if pt is used at low temperatures. for example, using the pt at temperatures of 0 c will reduce the service life to approximatel y 10,000 hours (ref erence value). *3. lot no. 28x1 or later of ns8 models, lot no. 11y1 or later of ns10 models, lot no. 14z1 or later of ns12 models, lot no. 31114k or later of ns15 models. *4. this function does not indicate that the service life has been reached. it detects when the backlight is not lit due to a disco nnection or other errors. backlight error detection indicates that all backlights (2) are off. *5. an analog touch panel is used with the ns15. do not press the touch panel in two or more places simultaneously. if the touch panel is pressed in two or mo re places simultaneously, it may activate a switch between the points that are presse d. series ns8-v2 ns10-v2 ns12-v2 ns15-v2 model ns8- tv00- v2 ns8- tv01- v2 ns8- tv00b -v2 ns8- tv01b -v2 ns10- tv00- v2 ns10- tv01- v2 ns10- tv00b -v2 ns10- tv01b -v2 ns12- ts00- v2 ns12- ts01- v2 ns12- ts00b -v2 ns12- ts01b -v2 ns15- tx01s- v2 ns15- tx01b- v2 built-in ethernet port no yes no yes no yes no yes no yes no yes yes yes case color ivory black ivory black ivory black silver black display device high-definition tft color lcd high-definition tft color lcd high-definition tft color lcd high-definition tft color lcd effective display area width 170.9 height 128.2 mm (8.4 inches) width 215.2 height 162.4 mm (10.4 inches) width 246.0 height 184.5 mm (12.1 inches) width 304.1 height 228.1 mm (15 inches) display colors 256 colors number of dots 640 dot horizontal 480 dot vertical 800 dot horizontal 600 dot vertical 1,024 dot horizontal 768 dot vertical view angle left/right: 80 , top: 80 , bottom: 60 *3 left/right: 70 , top: 65 , bottom: 65 *3 left/right: 80 , top: 80 , bottom: 80 *3 left/right: 80 , top: 70 , bottom: 60 screen data capacity 60 mbytes image data (bmp or jpg images) 32,768 colors memory card supported ladder monitor function supported video input unit support supported (image displayed via video input is 260,000 colors) (only rgb input is enabled.) controller link interface unit (wired) support not supported supported backlight *1 service life * 2 50,000 hours min. brightness adjustment three-level or 32-level brightness adjustment from the touch panel screen. * 3 backlight error detection *4 error is detected automatically, and the run indicator flashes green as notification. touch panel (matrix type) method matrix resistive membrane analog resistive membrane *5 number of switches/ resolution 768 (32 horizontal 24 vertical) 20 20 dots for each switch 1,200 (40 horizontal 30 vertical) 16 16 dots for each switch 1,900 (50 horizontal 38 vertical) 16 16 dots for each switch resolution: 1,024 (horizontal) 1,024 (vertical) input pressure-sensitive service life 1,000,000 touch operations. display text labels can be specified in cx-designer. font, style, and size can be specified. numerals, alarms, and character strings scalable gothic: magnification: 6 to 255 points rough: magnification: 1 1, 1 2, 2 1, 2 2, 3 3, 4 4, 8 8 standard: magnification: 1 1, 1 2, 2 1, 2 2, 3 3, 4 4, 8 8 fine: magnification: 1 1, 1 2, 2 1, 2 2, 3 3, 4 4, 8 8 7-segment display: can display only numerals, dates, and times. supported languages (42 languages) scalable gothic, rough, standard, and fine can be used for 42 languages. japanese, simplified chinese, traditional chinese, korean, englis h, french, german, italian, portuguese, spain, swedish, dutch, finnish, norwegian, basque, catalan, danish, albanian, croat ian, czech, hungarian, polish, romanian, slovak, slovenian, bulgarian, belarusian, russian, serbian, macedonian, ukrainia n, georgian, icelandic, afrikaans , faroese, indonesian, greek, turkish, estonian, latvian, lithuanian, thai (supported only with scalable gothic font) text attributes color 256 colors font style (only when vector font is specified) bold or italic vertical alignment top, center, or bottom horizontal alignment left-justified, centered, or right-justified flicker objects supporting flicker functional objects: select from up to 10 types of registered flicker settings. the flicker speed and flicker range can be set. fixed objects: select fr om three flicker types. numeral units and scale settings 1.000 max. alarm/event settings 5,000 max. expansion interface for expansion interface units
ns series 14 communications ns5/ns8/ns10/ns12/ns15 *1. except ns5. *2. ns @ - @@@ 1- v 2 only. *3. except ns5 and ns 8. *4. except ns5 and ns15. ns15 pr ovides rgb input. (ns-ca002) memory card interface one ata-compact flash interface slot functions used to transfer and store screen data, store logging data, and store history data. (alarm/event history, operation log, and error log generated during macro execution). serial communications port a connector conforms to eia rs-232c. d-sub female 9-pin connector 5- v output (250 ma max.) through pin 6. the 5- v outputs of serial ports a and b cannot be used at the same time. functions host (plc) access: 1:n nt links (connections with cs/cj/cp-series plcs and c200hx/hg/he(-z) plcs), 1:1 nt links, or host link (connections with c series or c v m1/c v -series plcs) direct access to temperature controllers using smart active parts: compoway / f and bar code reader connections (read directly from display.) port b connector conforms to eia rs-232c. d-sub female 9-pin connector. 5- v output (250 ma max.) through pin 6. the 5- v outputs of serial ports a and b cannot be used at the same time. functions host (plc) access: 1:n nt links (connections with cs /cj/cp-series plcs and c200hx/hg/he(-z) plcs) or 1:1 nt links (connections with c series or c v m1/c v -series plcs) direct access to temperature controllers using smart active parts: compoway / f and bar code reader connections (read directly from display.) usb slave specifications usb rating usb1.1 connector type-b (slave) functions connection with the cx-designer (for screen data tran sfers) connecting to a pictbridge-compatible printer recommended printers: epson: pm-g4500, px-g5300, px-5600, ep-901f canon: pixus mx7600, pixus ip100, pixus ix5000 usb host specifications *1 usb rating usb1.1 connector type-a (host) functions connection with a printer (for hard copies) recommended printers: epson: px-g930 built-in ethernet specifications *2 conformance standards conforms to ieee 8 02.3/ethernet (10 base-t/100 base-tx). functions host (plc) access and connection with t he cx-designer (for screen data transfers) controller link (wired- type) specifications *3 baud rate 2 m/1 m/500 k bps transmission path shielded twisted-pair cable (special cable) functions host (plc) access and data links video input specifications *4 resolution ns-ca001: 320 240, 640 48 0, 8 00 600 dots ns-ca002: user-defined size input signal ns-ca001: ntsc composite video or pal ns-ca002: ntsc composite video or pal number of video inputs ns-ca001: number of cameras: 4 max. ns-ca002: 2 cameras + rgb
ns series 15 connectable devices supported omron plcs note: including models whose produc tion were discontinued. *1. to connect a ns with a plc via a rs-422a connection, omron ' s ns-al002, or cj1 w -cif11 rs-232c/rs-422a converter can be used to convert the rs-232c port on the ns to rs-422a. *2. a ns with ethernet port is necessary. w hen connecting a plc with the ns, an ethernet por t is necessary on the plc, too. use a plc cpu unit with a built-in ethernet po rt, or add an ethernet unit. *3. a ns with ethernet port is necessary. w hen connecting a plc with the ns, an ethernet/ip port is necessary on the plc, too. use a plc cpu unit with a built-in ethernet /ip port, or add an ethernet/ip unit. *4. install a controller link interface unit on the ns . a controller link unit is necessary for the plc. *5. mount a serial communications unit on the nj-series controller. a ns can access only to the controller ' s memory used for cj-series unit. *6. w hen using a ethernet/ip unit to connect the nj-series controller, nj troubleshooter is not supported. plc series plc model name rs-232c *1 ethernet controller link *4 1:1 nt link 1:n nt link host link fins *2 ethernet/ip *3 c series cqm1 yes no yes no no no cqm1h yes yes yes no no yes cpm1 yes no yes no no no cpm1a yes no no no no no c p m 2 a y e sn oy e sn on on o c p m 2 c y e sn oy e sn on on o c200hs yes no yes no no no c200he (-z) yes yes yes no no yes c200hg (z) yes yes yes no no yes c200hx (-z) yes yes yes no no yes c v m1/c v series c v 500/1000/2000 yes no yes yes no yes c v m1 yes no yes yes no yes cs series cs1h no yes yes yes yes yes cs1g no yes yes yes yes yes cs1d no yes yes yes yes yes cj series cj1h no yes yes yes yes yes cj1g no yes yes yes yes yes cj1m no yes yes yes yes yes cj2h no yes yes yes yes yes cj2m no yes yes yes yes yes cp series cp1h no yes yes yes yes no cp1l no yes yes yes no no cp1e no yes yes no no no nj series nj5/nj3/nj1 yes *5 yes *5 yes *5 no yes *6 no nx series nx7 no no no no yes no
ns series 16 function comparison note: including models whose produ ction were discontinued. *1. the spma relaying a plc is not supported. *2. only device monitor function is suppor ted. monitoring function that uses tags (variables) is not supported. *3. the sap for cj-series special i/o units and cpu bus units t hat can be used with nj-series controller is supported. *4. sysmac studio version 1.02 or higher (cx-designer version 3.41 or higher) is required. plc series plc model name ladder monitor device monitor/ switch box plc data trace spma sap ethernet/ip tag access (network symbols) plc troubleshooter nj troubleshooter/ integrated NS-SERIES pt simulation *4 c series cqm1 no no no no no no no no c q m 1 h n on on on on on o n o n o cpm1 no no no no no no no no c p m 1 a n on on on on on o n o n o c p m 2 a n on on on on on o n o n o c p m 2 c n on on on on on o n o n o c200hs no no no no no no no no c 2 0 0 h e ( - z ) n on on on on on o n o n o c 2 0 0 h g ( - z ) n on on on on on o n o n o c 2 0 0 h x ( - z ) n on on on on on o n o n o cvm1/cv series cv500/1000/2000 no no no no no no no no cvm1 no no no no no no no no cs series cs1h yes yes yes yes yes no yes no cs1g yes yes yes yes yes no yes no cs1d yes yes yes yes yes no yes no cj series cj1h yes yes yes yes yes no yes no cj1g yes yes yes yes yes no yes no cj1m yes yes yes yes yes no yes no cj2h yes yes yes yes yes yes yes no cj2m yes yes yes yes yes yes yes no cp series cp1h yes yes yes yes *1 yes no no no cp1l yes yes yes yes *1 yes no no no cp1e no no no yes *1 yes no no no nj series nj5/nj3/nj1 no yes *2 no no yes *3 yes no yes nx series nx7 no no no no no yes no yes
ns series 17 connectable inverters connectable temperature controllers the following temperature controllers can be connected directly to an NS-SERIES pt*. note: including models whose produc tion were discontinued. * the ns-runtime cannot be connected dire ctly to a temperature controller. series communication unit connection 3g3mx2-v1 (use the rs-485 terminal on the inverter) rs-485 (2-wire) 1:n 3g3jx (use the rs-485 connector on the inverter) 3g3rx-v1 (use the rs-485 terminal on the inverter) unit name series model remarks modular temperature controller ej1 ej1-edu end unit sap screens are available. modular temperature controller e5zn e5zn-sct24s terminal unit digital controller e5ar e5ar- @@@@@@@@@ -flk e5er e5er- @@@@@@@@@ -flk temperature controller (digital controller) e5an/e5en/e5cn (basic model) e5cn- @@@@@ t-flk multi-input (thermocouple/resistance thermometer) type e5cn- @@@@@ l-flk analog input type e5en- @@@@@ t-flk multi-input (thermocouple/resistance thermometer) type e5en- @@@@@ l-flk analog input type e5an- @@@@@ t-flk multi-input (thermocouple/resistance thermometer) type e5an- @@@@@ l-flk analog input type e5an-h/e5en-h/ e5cn-h (advanced model) e5cn-h @@@@@@@ -flk universal-input model e5en-h @@@@@@@@ -flk universal-input model e5an-h @@@@@@@@ -flk universal-input model e5gn e5gn- @@@ tc-flk thermocouple input type e5gn- @@@ p-flk resistance thermometer input type
ns series 18 connecting to another company?s plc *1. to connect using rs-422a/4 8 5, an rs-232c/422a converter (e.g . ns-al002, cj1w-cif11) is required. *2. to connect using rs-4 8 5, an rs-232c/422a converter (e.g. ns -al002, cj1w-cif11) is required. up to 32 sequencers can be connected when using rs-4 85. manufacturer series cpu communication unit/adapter/board connection diagram mitsubishi electric a series a1shcpu a2uscpu a2ushcpu-s1 computer link unit a1sj71uc24-r @ a1sj71uc24-prf rs-232c, rs422a/4 8 5 *1 1:1 a2acpu computer link unit aj71uc24 fx series fx0n fx1s fx1n fx1nc fx2n fx3uc fx3g communication special adapter fx3u-232-adp fx2nc-232adp fx0n-232-adp communication expansion board fx @@ -232-bd rs-232c, rs422a/4 8 5 *1 1:1 q/qna series q00cpu q01cpu rs-232c port on the cpu module rs-232c 1:1 q00cpu q01cpu q00jcpu q02cpu q02hcpu q06hcpu q12hcpu q25hcpu q03udcpu q06udhcpu q13udhcpu serial communications module qj71c24n-r2 qj71c24n-r4 qj71c24n rs-232c, rs-4 8 5 (4-wire) *2 1:n q2ascpu q2ascpu-s1 q2ashcpu q2ashcpu-s1 serial communications module a1sj71qc24n yokogawa electric fa-m3(r) series f3sc23-1f f3sp21-0n f3sp2 8 -3s f3sp5 8 -6s f3sp67-6s cpu built-in rs-232c port rs-232c 1:1 personal computer link module f3lc11-1f f3lc12-1f f3lc11-2f rs-232c, rs-422a/4 8 5 *1 siemens s7-300 series cpu313 cpu315-2dp cpu317-2pn/dp simatic s7 hmi adapter 6es7 972-0ca1 @ -0xa0 rs-232c 1:1 rockwell (allen-bradley) slc500 slc5/03 slc5/04 slc5/05 rs-232c port on the cpu module rs-232c 1:1 micrologix micrologix 1500 rs-232c port on the cpu module rs-232c 1:1 controllogix logix5555 rs-232c port on the cpu module rs-232c 1:1 compactlogix 1769-l31 rs-232c port on the cpu module rs-232c 1:1 plc-5 plc-5/20 rs-232c port or rs-4 8 5 port on the cpu module rs-232c/rs-4 8 5 (4-wire) 1:n
ns series 19 component names and options ns15 ns12/10 ns8 memory card interface note: colors shown in photographs and product names may differ from actual colors and names. memory card expansion interface battery rs-232c serial port b rs-232c serial port a a bar code reader can be connected to the serial port. recommended bar code reader: v520-rh21-6 analog rgb output ethernet (10 base-t or 100 base-tx) usb slave (for transferring screens and connecting a pictbridge-compatible printer) usb host (for printer) po wer supply (24 vdc) connector for brightness adjustment rs-422a/485 serial interface usb slave (for transferring screens and connecting a pictbridge-compatible printer) usb host (for printer) battery po wer supply (24 vdc) rs-232c serial port b rs-232c serial port a expansion interface memory card interface ethernet (10 base-t or 100 base-tx) note: colors shown in photographs and product names may differ from actual colors and names. memory card a bar code reader can be connected to the serial port. recommended bar code reader: v520-rh21-6 po wer supply (24 vdc) expansion interface battery memory card interface rs-232c serial port a rs-232c serial port b ethernet (10 base-t or 100 base-tx) usb slave (for transferring screens and connecting a pictbridge-compatible printer) usb host (for printer) note: colors shown in photographs and product names may differ from actual colors and names. memory card a bar code reader can be connected to the serial port. recommended bar code reader: v520-rh21-6
ns series 20 ns5 nsh5 optional products po wer supply (24 vdc) battery ethernet (10 base-t or 100 base-tx) usb slave (for transferring screens and connecting a pictbridge-compatible printer) rs-232c serial port a rs-232c serial port b memory card interface expansion interface note: colors shown in photographs and product names may differ from actual colors and names. memory card a bar code reader can be connected to the serial port. recommended bar code reader: v520-rh21-6 enable switch led memory card interface emergency stop switch hand strap function switches usb port cable video input unit ns-ca001 (with cover) rgb/video input unit ns-ca002 (with cover) controller link interface unit ns-clk21 (with cover) rs-422a adapter cj1w-cif11 rs-232c/rs-422a conversion unit ns-al002 communications cable xw2z-s002 protective cover/anti-reflection sheet for NS-SERIES pt ns-kba0 (n) nt30/nt31c-kba05 (n) usb serial conversion cable cs1w-cif31 usb relay cable (ip65 oil-proof type) ns-usbext-1m
ns series 21 dimensions (units: mm) rda rdb sda sdb rsa rsb 383.5 +1 ?0 282.5 +1 ?0 ru n mounting panel mounting bracket recommended panel cutout dimensions 405 304 71.8 57.31 27.4 340 405.5 383 304.5 282 8 37.9 (min.) 41.1 (max.) 15.5 94.8 79.54 13.95 84.1 170 39.4 86.83 85.6 46 3.8 70 75.8 ns15 228 +1 ?0 7.5 48.5 39 (min.) 42 (max.) 15.5 121 134 264 323 315 301 241 227 249 140 302 +1 ?0 slave host dc 24v reset sw ethernet port a port b 49.9 13.7 23 3.8 90.4 49 recommended panel cutout dimensions ns12/10 5 48.5 39 (min.) 42 (max.) 232 180 15.5 220 165 188 177 63.4 44.1 50.1 165.5 +0.5 ?0 220.5 +0.5 ?0 ethernet port a sw port b reset host dc 24v 19.1 107.6 120.5 26.6 9.6 49 recommended panel cutout dimensions ns8 195 39.83 27.3 90 142 15.5 145 206.3 183.5 77 51.7 19.5 21 153.3 130.5 5 34 (min.) 38 (max.) 54.8 53.8 131 +0.5 ?0 184 +0.5 ?0 ru n ether n et 44.55 68.48 recommended panel cutout dimensions ns5
ns series 22 related manuals cat. no. model manual v08 3 ns15/ns12/ns10/ns 8 /ns5 NS-SERIES programmable terminals setup manual v 073 ns15/ns12/ns10/ns 8 /ns5 NS-SERIES programmable terminals programming manual v 099 ns-cxdc1- v 3 cx-designer v er.3. @ user's manual v08 2 ns NS-SERIES ladder monitor operation manual (ladder monitor i/o comment extracting tool) v08 6 ns-ca002 NS-SERIES rgb and v ideo input unit operation manual v 090 nsh5 nsh5-series hand-held programmable terminal operation manual v 098 ns15/ns12/ns10/ns 8 /ns5 NS-SERIES programmable terminals host connection manual (host link) operation manual v08 5 ns15/ns12/ns10/ns 8 /ns5 NS-SERIES programmable terminals host connection manual v 092 ns15/ns12/ns10/ns 8 /ns5 NS-SERIES programmable terminals host connection manual multivendor connection v 075 ns15/ns12/ns10/ns 8 /ns5 NS-SERIES programmable terminals macro reference v 093 ns-nsrcl @@ ns-nsrcl @@ ns-runtime software users manual 223 75 16.5 176 75 50 70.5 hand-held ns5 5 9.6 81.3 (102.7) 164 (169) 21.4 (22.3) (1.9) 20.4 11 10.6 9.7 127.3 50.3 68.3 86.3 104.3 ns-ca001 video input unit 9.6 5 164 (169) 81.3 (102.7) 21.4 39.3 57.3 82.8 118.3 20.4 11 9.7 (22.3) (1.9) 11.1 ns-ca002 video input unit 5 (183) 151.5 31.5 164 (169) 11 10.8 32 95.6 (33.9) (1.9) ns-clk21 controller link interface unit
read and understand this catalog please read and understand this catalog before purchasing the products. please consult your omron repr esentative if you have an y questions or comments. warranty and limitations of liability warranty omron's exclusive warranty is t hat the products are free from defects in mate rials and workmanship for a period of one year (or other period if specified) from date of sale by omron. omron makes no warranty or representation, expr ess or implied, regarding non-infringement, merchantability, or fitness for particular purpose of the products. any buyer or user acknowledges that the buyer or user alone has determined that the pr oducts will suitably meet the requirements of their intended use. omron disclaims all other warranties, express or implied. limitations of liability omron shall not be responsible for special, indirect, or consequential damages, loss of profits or commercial loss in any way connected with the products, whether such claim is based on contract, warranty, negligence, or strict liability. in no event shall the responsibility of omron for any act exc eed the individual price of the pr oduct on which liabi lity is asse rted. in no event shall omron be responsible for warranty, repai r, or other claims regarding the products unless omron's analysis confirms that the products were pro perly handled, stored, installed, and maintained and not subject to contamination, abuse, misuse, or inappropriate modification or repair. application considerations suitability for use omron shall not be responsible for conformity with any standards, codes, or regulati ons that apply to the combination of produc ts in the customer's application or use of the products. at the customer's request, omron will pr ovide applicable third party ce rtification documents identifying ratings and limitation s of use that apply to the products. this information by itself is not sufficient for a complete determination of the suitability of the products in c ombination with the end product, machine, system, or other application or use. the following are some examples of applicat ions for which particular attention must be given. this is not intended to be an exh austive list of all possible uses of the products, nor is it intended to impl y that the uses listed may be suitable for the products: ? outdoor use, uses involving potential chem ical contamination or electr ical interference, or conditi ons or uses not described in this catalog. ? nuclear energy control systems, combustion systems, railroad systems, av iation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. ? systems, machines, and equipment that coul d present a risk to life or property. please know and observe all prohibitions of use applicable to the products. never use the products for an application involving seri ous risk to life or property without ensuring that the system as a whole has been designed to address the risks, and that the omron products are properly rated and installed for the intended use within the overall equipment or system. programmable products omron shall not be responsible for t he user's programming of a programmabl e product, or any consequence thereof. disclaimers change in specifications product specifications and ac cessories may be changed at any time based on improvements and other reasons. it is our practice to change model numbers when published ratings or features are changed, or when signific ant construction cha nges are made. however, some specifications of the products may be changed with out any notice. when in doubt, special model numbers may be ass igned to fix or establish key specifications for your application on your request. please consult with y our omron representative at any time to confirm actual specifications of purchased products. dimensions and weights dimensions and weights are nominal and are not to be used for manufacturing pur poses, even when tolerances are shown. performance data performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. it may represent the result of omron?fs test c onditions, and the users must correlate it to actual application r equirements. actual performance is subject to the omron warranty and limitations of liability. errors and omissions the information in this document has been carefully checked and is believed to be accurate; how ever, no responsibility is assum ed for clerical, typographical, or proofreading errors, or omissions. authorized distributor: in the interest of product improvement, specifications are subject to change without notice. cat. no. v405-e1-14 0712 (1206) ? omron corporation 2011 all rights reserved. omron corporation industrial automation company omron electronics llc one commerce drive schaum bu rg, il 60173-5302 u.s.a. tel: (1) 847-843-7900/fax: (1) 847-843-7787 regional headquarters omron europe b.v. wegalaan 67-69-2132 jd hoofddorp the netherlands tel: (31)2356-81-300/fax: (31)2356-81-388 contact: www.ia.omron.com tokyo, japan omron asia pacific pte. ltd. no. 438a alexandra road # 05-05/08 (lo bb y 2), alexandra technopark, singapore 119967 tel: (65) 6835-3011/fax: (65) 6835-2711 omron (china) co., ltd. room 2211, bank of china tower, 200 yin cheng zhong road, pudong new area, shanghai, 200120, china tel: (86) 21-5037-2222/fax: (86) 21-5037-2200 note: do not use this document to operate the unit. csm_11_3_0915


▲Up To Search▲   

 
Price & Availability of NS-SERIES

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X